The Autrol APT3100-D provides
differential pressure measurement
calibrated spans of 0.3" H2O upto
a max. of 1,000 psiD. Internal
magnetic push buttons for
configuration of Zero/Span, Trim,
Unit, Fail-mode, etc. Five (5) digit
LCD, programmable and
engineering units. The superior
performance high reference
accuracy: +-0.075% of calibrated
span; long tern stability; 100:1
rangeability. CSA Approved. |
The Autrol APT3200-G-A provides
gauge pressure measurement
calibrated spans of 0.2 psig upto a
max. of 6,000 psig, and Absolute
pressure ranges 0 to 362.5 psia.
The superior performance high
reference accuracy: +-0.075% of
calibrated span; long tern stability;
100:1 rangeability. Digital
communication with HART
protocol. Provides your application
requirements with optimum
performance. |
The Autrol ATT2100 smart temperature
transmitter is a microprocessor based high
performance transmitter, which has flexible
sensor input and output, automatic
compensation of ambient temperature and
process parameters, configuration of various
parameters, and communication with HART
protocol. All data of sensor (tag number, type,
range, etc.) is to be inputted, modified and
stored in EEPROM. |
The Autrol APT3100L direct mount
smart transmitter with diaphragm
seal for measuring hydrostatic pressure head and transmitting
liquid level. Flush diaphragm seal
and direct or remote capillary type
mounting arrangements to suite the
installation requirements. Flush
diaphragm seal with tri-clamp type
sanitary process connection also
available for sanitary type
installations. Superior performance,
flexibility and reliability
characteristics are featured with the
APT3200L series transmitter.
|
The Autrol APT3700N smart
transmitter for nuclear service is
designed in accordance with KEOIC-QAP & KEPIC-EN quality
assurance program. Nuclear
cleaning to 1 ppm chloride content;
seismic accuracy within +-0.25% of
upper range limit during and after
seismic disturbance of 1 SSE and
5 OBE. All Transmitters
hydrostatically tested for a min of
10 minutes at 1.5 times the design
pressure with no detectable
leakage for Class 1E safety related
applications.
|
|